Journal of Acupuncture and Meridian Studies
Volume 2, Issue 2 , Pages 152-158, June 2009

Magnetic Resonance Imaging and Acupuncture: A Feasibility Study on the Migration of Tracers after Injection at Acupoints of Small Animals

  • Jungdae Kim

      Affiliations

    • Research Institute of Basic Sciences, Seoul National University, Seoul, Korea
  • ,
  • Kyoung-Hee Bae

      Affiliations

    • Department of Physical Education, University of Incheon Graduate School, Incheon, Korea
    • Corresponding Author InformationCorresponding author. Department of Physical Education, University of Incheon Graduate School, Incheon 402-749, Korea
  • ,
  • Kwan-Soo Hong

      Affiliations

    • Bio-MR Research Center, Korea Basic Science Institute, Yangcheong-Ri, Ochang-Eup, Cheongwon-Gun, Chungcheongbuk-Do, Korea
  • ,
  • Sang-Chul Han

      Affiliations

    • Department of Physical Education, University of Incheon Graduate School, Incheon, Korea
  • ,
  • Kwang-Sup Soh

      Affiliations

    • Department of Physics & Astronomy, Seoul National University, Seoul, Korea

Received 28 November 2008; accepted 15 April 2009.

Abstract 

Objectives

Acupuncture meridians in traditional Oriental medicine are known to be channels connecting specific points in the surface of the body to corresponding internal organs. We investigated the permeation and the transport of magnetic resonance imaging (MRI) contrast agent and tracer after injection at acupoints of small animals, such as rats and mice.

Methods

A geometric and systematic arrangement of acupuncture points on human skin surfaces has been depicted in traditional Oriental medicine, and the positions of the acupoints of small animals were determined by the application of a proportion on the animals corresponding to the morphological structures in humans. After injecting the materials at various acupoints, the agent migration behaviors inside the body were monitored by MRI. The distributions of the injected materials were reconstructed in 3-dimensional images for a more intuitive presentation.

Results

The widely-used gadolinium-compound contrast agent was not useful. Rather, a recently developed fluorine compound was effective for imaging the migration of the agent after injection into the acupoints BL18, 20, and 23.

Conclusions

The final distributions of the agent from each injection point corresponded to the respective organs of the acupoints. The results suggested different migration paths and destinations for pharmacopuncture drugs.

Key words:  acupuncture , gadolinium , magnetic resonance imaging , mice , perfluoro-15 crown-5 ether , rats

 